Recirculating air filter system UFA.025.030 with exhaust air monitoring

Recirculating air filter system – avoid complex wall breakthroughs and expensive exhaust air ducts

  • High flexibility in choosing the installation location
  • Active personal protection through safe capture of harmful vapours with retention in the filter system
  • Very low noise, only approx. 23 dB (A)
  • ATEX compliant: C` II 3/-G Ex ic nA IIB T4 Gc
  • Housing made of sheet-steel powder-coated
  • With multi-stage filter system, secondary filter, connection cable and mains plug
  • Incl. monitoring electronics for exhaust air and filter monitoring and display for status and error indication
  • Key control panel for navigation of the functions and status query
  • Optical and acoustic alarm including potential-free alarm contact
  • Successfully tested by the certified testing institute

The plug-in recirculating air filter system, type UFA.20.30 is capable of retaining solvent vapours (hydrocarbons) permanently up to a filter saturation of more than 99.999%, under normal operating conditions as well as for a simulated accident in the safety storage cabinet.


characterstics
  • W x D x H (mm): 308 x 555 x 256


Please note the country-specific terms of use that are binding for you. In case of doubt, possible uses must be agreed with the competent authority.

Your selected product

Order No. 39306
* Information on Delivery and Price NOTE:
When configuring a safety cabinet, please adhere to the applicable national rules and regulations for the storage of hazardous substances. If you are unsure, the asecos experts will be happy to help you further.

PRICE INFORMATION:
All prices are net prices and are subject to VAT.
All prices are only valid for UK mainland, excluding islands (price on application).
All prices are subject to a surcharge for remote areas.

¹ Ex works: The item price does not include delivery and delivery costs.
² Behind first door: The item price includes free delivery to behind the first locked door.
³ To point of use: The item price includes free delivery to final point of use.

REMOTE AREAS:
Scotland:
AB, DD, FK, HS, IV, KW, KY, PA, PH and ZE is price on appliaction
England: EX, PL, TQ, TR
Wales: all postcodes except CF, LL11-LL14, NP and SA1-SA15

In the event that material and auxiliary materials, freight, toll, customs and energy costs, wages, etc. increase unforeseeably during the term of the contract, we reserve the right to increase or recalculate the price accordingly.

When separate or additional orders of accessories and cabinet interiors (eg. shelves, perforated metal plate, etc.) are placed the purchase price is ex works plus packaging, freight costs and VAT (In consideration of the size and weight we will choose the best shipping method for you).

Did you know ...

Technical Data

External dimensions W x D x H 308 x 555 x 256 mm
Weight 18 kg
Min. volume flow 10 m³/h
Volume flow 10 m³/h
Max. volume flow 10 m³/h
Nominal Power Consumption 8,5 W
Nominal voltage 85-265 V
Emission sound pressure level 23 dB
Maximum current consumption 0.13 A
Frequency 50/60 Hz
Potential-free alarm contact: maximum continous current 10 A
Potential-free alarm contact: maximun nominal voltage AC 230 V
Potential-free alarm contact: maximum nominal voltage DC 30 V
Potential-free alarm contact: single-phase motor load 185 W
Potential-free alarm contact: max. switching capacity (electromagnetic) 300 VA
Potential-free alarm contact: max. switching capacity (ohmic) 1,500 VA
Potential-free alarm contact Yes (1)
ATEX label II 3/- G Ex ic nA IIB T4Gc
explosion-proof Yes
exhaust air monitoring Yes (1)
Filter type activated carbon
Filter monitoring yes
ecl@ss 11.0 22-41-90-90
Customs tariff number 84213925
GTIN 4250101190117